Electronic Load 150W 10A Adjustable Current with 2.2'' LCM #EE. X13454

Electronic Load 150W 10A Adjustable Current with 2.2'' LCM #EE. X13454

Regular price 35,000 IQD
Regular price Sale price 35,000 IQD
Sale تم نفاذ المنتج
Electronic Load 150W 10A Adjustable Current with 2.2'' LCM

حهاز لود الكتروني بقدرة 150 واط و 10 امبير 
يستخدم لقياس سعة البطاريات بمختلف انواعها 
وقياس جودة مجهزالت القدرة وقياس التيار الفعلي 
مهم جدا لكل من يعمل في تصنيع وصيانة مجهزات القدرة ومخازن البطاريات 
يحتوي على منفذ USB  و  Mini USB  و Micro USB  و Type-C hاضافة للكونكتر 

يتوفر بسعر 35,000 دينار 




 Specifications:
 
PowerVoltage:DC6~12V   Interface:DC5.0
Voltage measure range:0~150V Accuracy:0.05V
Current adjustable range:0~10A Accuracy:0.05A
Capacity range:0~999.999Ah  Accuracy:0.001Ah
Cumulative range:0~99999.9Wh Accuracy:0.01Wh
Measure range:0~2999.9W Accuracy:0.01W
Impedance range:0~999.9Ω Accuracy:0.01Ω
Temperature range:0~99℃ Accuracy:1℃  
Max timing :999:59:59  Accuracy:1s
Fan cooling power:<150W
Fan control threshold:Temp>40℃
Standby reminder threshold:<2W/0.5h;
Timing function:>0.5W start timing
Input interface: 20A high current occlusion screw column, type A USB,Mini USB, Micro USB, Type-C USB
Refresh time:>500ms/time  
Measurement rate: 0.5time/s
Over limit alarm: interface warning and buzzer alarm
Voltage overrun auto- stops discharge range:0~150V
Current overrun auto- stops discharge range:0~10A
Power overrun auto- stops discharge range:0~150W
Display screen: LCM display
Size:149×96×80mm/195×105×135mm(package)
Weight:570g(package)/370g(net weight)
Consumption:<1.5A    
Operating temp:-10~60℃
Operating  humidity:10~80(No condensation)
 
Mode button function description:
1. Click to switch each display interface
2. The function of the button operation in the 2-4 interface is as follows:
   Long press all records to clear;
   Double-click capacity (Ah) to reset to zero;
   Three-stroke power (Wh) reset to zero;
   Four-stroke power (00:00:00) reset to zero;
   Consecutive seven hits at no load, making the current zero accurate in the current temperature environment.Calibration is zeroed for accurate measurement at low currents;Factory reset all parameters.
3. The operation functions of the buttons under the interfaces 6, 7, 9, 11, and 13 are as follows:
   Double-click the parameter value to increase, double-click and long press the parameter to continue to increase;
   The value of the three-stroke parameter is reduced, and the length of the three-stroke is continued to decrease.
 
How to use:
Input voltage × current ≤ 150W;
Turn on the load power supply, and the coarse and fine adjustment knobs will be reset to zero (counterclockwise to the end)
Long press the mode button to clear all data;
Connect to the power supply under test, and use the fine adjustment knob to slowly adjust the discharge current.When the fine adjustment cannot meet the current value, the fine adjustment is reset to zero, and the coarse adjustment knob is slowly adjusted.And with fine adjustment until the required current value is reached.
It is recommended to set the cutoff voltage (lower voltage input) when the battery is discharged.In order to avoid damage caused by excessive discharge. 